Tri-State Distribution Center I-95 is a modern 525,000-square-foot warehouse and distribution facility on a 36.36-acre lot. Built in 2025, this Class A building offers 267 parking spaces with a parking ratio of 0.51. Designed for efficiency and large-scale operations, the facility is ideal for tenants seeking expansive industrial space with ample parking accommodations.
Situated at 333 Naamans Road in Claymont, DE, the property is within approximately half a mile of a Shell fuel station and a Tesla Supercharger, with additional fueling options under 2 miles away. NCT Parking is about 1.9 miles away, providing nearby parking alternatives for larger fleets or visitors. While the Wilmington public transportation station is approximately 7.7 miles from the site, additional parking facilities in Wilmington and surrounding areas range between 5 to 7 miles.
True
1 Space Available
#A
Warehouse/Distribution
Contact for pricing
525,000 SF
525,000 - 525,000 SF
270
Immediate
Yes
No
-
Divisible for up to 4 tenants.
Move in reasdy with toilet rooms and office build out.
Land Area 36.4 Acres
Building Area 525,000 SF
Dimensions 525’ D x 1,000’ W
Office Area 3,050 SF spec office with remote restrooms
Clear Height 40’
Column Spacing 54’ W x 50’7.5” D with 58’10” D speed bays
Dock Doors 97 (9’ x 10’) insulated overhead dock door
Dock Equipment 49 dock doors outfitted with 45,000 lb.mechanical levelers, seals and bumpers
Drive-In Doors 4 (12’ x 14’) electronically operated doors
Truck Court
Depth 140’ - 198’ on north end 198’ on south endTrailer Parking 108 dedicated stalls
Car Parking 270 spaces
Construction Exterior walls are tilt-up concrete panels; structural steel
Roof Fully adhered TPO, mechanically fastened R20 insulation; metal decking
Floor 7” thick unreinforced concrete, minimum 4,000 PSI compressive strength
Lighting LED fixtures on motion sensors; 30 foot candles at 36” AFF
Fire Protection ESFR system
Power One (1) 2500kVA & one (1) 2000kVA, 3-phase/4-wire services
HVAC Gas-fired rooftop heating units (55 degrees inside at 0 degrees outside). One (1) air change per hour
40'
54' W x 50'7.5" D
97
4
3,050 SF
Exterior walls are tilt-up concrete panels; structural steel
One (1) 2500kVA & one (1) 2000kVA, 3-phase/4-wire services
ESFR